Generator Set Specifications
Minimum Rating
Maximum Rating
Emissions/Fuel Strategy
50 Hz Prime
50 Hz Standby
60 Hz Prime
60 Hz Standby
Frequency
Speed
Voltage
50 Hz Prime Rating
60 Hz Prime Rating
50 Hz Standby Rating
Engine Specifications
Engine Model
404D-22G
Bore
Stroke
Governor Type
Displacement
Compression Ratio
Fuel / Emissions Strategy
EUIIIa Emissions CompliantGenerator Set
- EUIIIa Emissions Compliant
- Complete System Designed And Built At ISO 9001 Certified Facility
- Factory Tested To Design Specifications At Full Load Conditions
Engine
- Governor, Mechanical
- Electrical System, 12V DC
- Cartridge Type Filters
- Fuel/Water Separator
- Battery, Rack And Cables
Alternator
- Insulation System, Class H
- Screen Protected And Drip-Proof, Self Exciting, Self-Regulating With Fully Interconnected Damper Windings, IC06 Cooling System And Sealed-For-Life Bearings
- Electrical Design In Accordance With BS5000 Part 99, IEC60034-1, EN61000-6, NEMA MG-1.22
Control System
- Manual/Autostart Control Panel
- Vibration Isolated, NEMA 1 Enclosure With Lockable Hinged Door
- DC And AC Wiring Harnesses
Multi-Voltage System
- Switchable Voltage Output:
- 480/277V 3 phase
- 208/120V 3 phase
- 240/120V 1 phase
- Convenience Receptacles
- Hinged Door Over Main Connectors
- NEMA 1 Steel Enclosure, Vibration Isolated
Circuit Breaker
Dual, 3-Pole With Solid Neutral, UL/CSA ListedMounting Arrangement
- Heavy-Duty Fabricated Steel Base Raised For Forklift Access
- Anti-Vibration Mounting Pads
- Complete OSHA Guarding
- Three-Way Valves To Allow Connection Of Auxiliary Fuel Tank
- UL Listed Single Walled Fuel Tank Base With 24 Hour Minimum Fuel Supply.
- Containment Area For Oil, Coolant And Fuel Spill.
Sound Attenuated Enclosure
- Fully Weatherproof Sound Attenuated Enclosure With Internal Exhaust Silencer
- Highly Corrosion Resistant Construction
Equipment Finish
- All Electroplated Hardware
- Anti-Corrosive Protection Prior To Painting
- High Gloss Polyurethane Paint For Durability And Scuff Resistance
Documentation
- Operation And Maintenance Manuals Provided
- Wiring Diagrams Included
- WARRANTY
Automatic Voltage Regulator
Voltage within the limits of +/- 0.5% for 3 Phase and +/- 1% for Single Phase operation at steady state from no load to full loadQuality Standards
IEC60034, EN61000-6, NEMA MG-1.22Optional Equipment
Engine
- Fuel tank - UL listed double wall tank base with 24 hour minimum supply
- Battery charger
- Electronic Governor required for operation at 60 Hz
Alternator
- Anti-Condensation Heater
Cooling System
- Engine Water heaters
Miscellaneous Accessories
- Additional operator's manual pack
Standard Equipment
24 Hour Fuel Tank
- Low Fuel Level Shutdown